混凝土面板坝渗漏值的
工程类比与评价方法
贾金生 ,郝巨涛 ,徐耀1,2
(1.中国水利水电科学研究院流域水循环模拟与调控国家重点实验室,
北京100038;2.中国大坝协会,北京100038)
摘要:渗漏评价是混凝土面板坝设计中的重要问题,对大坝的设计、运行管理及决策都有着重要意义。基于国内
外已建67座面板坝的运行监测成果,运用面板综合渗透系数法,提出了面板坝渗漏值的工程类比与评价方法,给出
了量化表达方式和算例,可供混凝土面板坝工程类比与评价参考。
关键词:面板坝;综合渗透系数;渗漏;评价方法
M ethod of Engineering Analogy and Evaluation Oil CFRDs Leakages
Jia Jinsheng 2,Hao Jutao ,Xu Yao ,
(1.State Key Laboratory of Simulation and Regulation of Water Cycle in River Basin,China Institute of Water Resources and
Hydropower Research,Beijing 100038,China;2.Chinese National Committee on Large Dams,Beijing 100038,China)
Abstract:Leakage evaluation of concrete face rockfill dam (CFRD)is an important issue in dam design,and has great
influence on dam design,operation and management and decision—making.Based on the monitoring data of 67 constructed
CFRDs in domestic and abroad,the engineering analogy and evaluation method on leakages of CFRD is proposed after
adopting the comprehensive permeability coeficient of concrete face,and a quantitative form ula and its application in a case
study are also given herein.The new method can be as reference to engineering analogy and evaluation of CFRD project.
Key Words:CFRD;comprehensive perm eability coeficient;leakage;evaluation method
中图分类号:TV641.43 文献标识码:A 文章编号:0559-9342(2011)10-0028-03
1 混凝土面板坝渗漏值的工程类比评价法
混凝土面板坝渗漏是不可避免的。渗漏量的大
小判断比较复杂,与工程情况、水库来水量的大小、
经济效益损失、有可能带来的安全问题等有关。在
面板坝发展的过程中, 如何确定渗漏量的允许值以
及如何控制渗漏量一直是工程界重点研究的问题。
对于抽水蓄能电站, 漏水量大意味着经济损失大:
对于常规水电站,漏水量大.最重要的是隐含了不
安全因素, 因此, 研究分析面板坝渗漏量的工程类
比并进行评价,对于大坝的设计、运行管理及决策
都具有重要意义。
估算混凝土面板的渗漏量可将混凝土面板假设
为一个均匀透水介质, 该介质的渗透性与面板的综
合防渗性能有关。它包括面板混凝土的渗透性、面
板开裂以及接缝渗漏情况等。这一假定的优点在于
琶阻Water Power Vo1.37 o.io
能够简便地对面板坝的渗漏进行评价, 其缺点是无
法反映面板的不均匀渗漏情况,如当面板周边缝渗
漏较大,特别是发生集中渗漏时,均化了的面板综
合渗透系数从而不能给出准确的渗漏位置和准确评
价。由于目前还没有比较全面的评价面板坝渗漏量
的方法,依据方便、简洁、简单的原则,笔者认为
按综合渗透系数法计算面板的渗透系数并对渗漏量
进行工程类比和评价是可行的,有一定的实用价值。
假定面板均匀透水
因本站资料资源较多,启用了多个文件服务器,如果浏览器下载较慢,请调用迅雷下载,特别是超过了5M以上的文件!请一定调用迅雷,有时候速度就会飞起哦,如果您的浏览器自动加载了PDF预览,文件太大又卡死,请按下载说明里的把PDF插件关闭了就可以直接下载,不会再预览了!